What was found
DURING C CHECK, LT ELEVATOR UPPER SURFACE HAS NON STANDARD REPAIR AT STA XE 32.937. PERFORMED MAJOR REPAIR IAW DC8 SRM 55-4-1 FIG 1. REMOVED PANEL PLATING WITH STANDARD REPAIR IAW DC8 SRM 55-1-0, DC8 SRM 51-1-21. FABRICATED NEW PLATING AND BONDED FINGER DOUBLER (AL 2024T3 0.016”) IAW DC8 SRM 55-4-1 FIG 1 (SHEET 1, 2) ITEMS “E”, “F”. BONDED BOTH PARTS WITH HYSOL IAW DC8 SRM 51-1-9, DC8 SRM 51-1-9A. CLEANED, TREATED AND PRIMED AREA AND NEW PANEL PLATING IAW DC8 SRM 51-1-8B. APPLIED SEALANT TO FAYING SURFACES IAW DC8 SRM 51-1-11. INSTALLED NEW PANEL PLATING IAW DC8 SRM 51-1-21, DC8 SRM 51-3-0, 51-3-1. PERFORMED BALANCE TO LT ELEV IAW DC8 SRM 51-4-4, FOUND WITHIN LIMITS. TABLE MOMENT 1.449. 37 IN LBS.