What was found
DURING ROUTINE C CHECK INSPECTION, MAIN CARGO COMPARTMENT- AFT FITTING CRACKED 3",AT STATION 680.000, LONGERON 11 RIGHT. REMOVED CRACKED FITTING IAW DC-8 SRM 51-1-20D. FABRICATED NEW FITTING IAW ATI REPAIR SPECIFICATION NR 2003-05, DOUGLAS DRAWING NR 4751625. PERFORMED NDT INSPECTION IAW DC8 NDT SPM PART 08-00-02 TO 07. CLEANED, TREATED, AND PRIMED AREA AND, NEW FITTING IAW DC8 SRM 51-1-8B. INSTALLED NEW FITTING IAW DC8 SRM 51-1-20D, DC8 SRM 51-1-23 (PLI-WASHER), DC8 SRM 51-3-1.