What was found
DURING ROUTINE C CHECK FOUND LEFT HAND WING INBOARD FLAP PLATING HAS NON STANDARD REPAIR FROM STATIONS XW 122.000 TO XW 125.000. PERFORMED MAJOR REPAIR IAW DC-8 SRM 57-7-1 FIG 1. REMOVED EXISTING PLATING WITH NON-STANDARD REPAIR IAW DC-8 SRM 57-1-0 PAGE 1, DC-8 SRM 51-1-21. FABRICATED NEW PLATING IAW DC-8 SRM 57-7-1 FIG 1 ITEM F. CLEANED, TREATED AND PRIMED AREA AND NEW PLATING INTERNAL PART IAW DC-8 SRM 51-1-8B. APPLIED NEW SEALANT TO FAYING SURFACES IAW DC-8 SRM 51-1-11. INSTALLED NEW PLATING IAW DC-8 SRM 51-1-21