What was found
DURING ROUTINE C CHECK INSPECTION FOUND MAIN CARGO COMPARTMENT FITTING CRACKED 1INCH FROM STATION 1100.000 TO STATION 1110.000 AT LONGERON 16 RIGHT. REMOVED CRACKED FITTING IAW DC8 SRM 51-1-20D. FABRICATED NEW FITTING IAW ATI REPAIR SPECIFICATION NUMBER 2003-05, DOUGLAS DRAWING 5755936. PERFORMED HEAT TREATMENT IAW DC8 SRM 51-1-1 PAGES 1, 13, AND 17. PERFORMED NDT INSPECTION IAW DC8 NDT SPM PART 08-00-02 TO 07. CLEANED, TREATED AND PRIMED AREA, AND NEW FITTING IAW DC8 SRM 51-1-8B. INSTALLED NEW SUPPORT IAW DC8 SRM 51-1-20D, DC8 SRM 51-3-1.