What was found
DURING ROUTINE C CHECK INSPECTION, RT ELEVATOR UPPER SKIN OIL CANNED, BETWEEN STATIONS XE 139.000 AND XE 252.000. PERFORMED MAJOR REPAIR IAW SRM 55-4-1 FIGURE 1 SHEET 1, AND 2. REMOVED DAMAGED SKIN, AND FINGER DOUBLER IAW SRM 51-1-21, SRM 55-1-0 PAGE 1. FABRICATED NEW SKIN. AND FINGER DOUBLER BOTH AL 2024T3 0.016” IAW SRM 55-4-1 FIGURE 1 SHEET 1, AND 2, ITEM E, AND F. BONDED BOTH PARTS WITH HYSOL IAW SRM 51-1-9. CLEANED, TREATED AND PRIMED AREA AND NEW REPAIR PARTS IAW SRM 51-1-8B. INSTALLED NEW REPAIR PARTS FROM STATION XE 132 TO STATION XE 246. IAW SRM 51.1.21.