What was found
DURING ROUTINE C CHECK INSPECTION FOUND RIGHT HAND ELEVATOR LT UPPER PANEL DEFORMED, TRAILING EDGE BROKEN 2 INCHES AND DELAMINATED AT STATION 28.843. PERFORMED MAJOR REPAIR IAW DC-8 SRM 55-4-1 SHEET 1, AND 2. REMOVED DAMAGED PANEL IAW DC-8 SRM 55-1-0, DC-8 SRM 51-1-21. FABRICATED NEW PANEL. CLEANED, TREATED AND PRIMED AREA, AND NEW PANEL IAW DC-8 SRM 51-1-8B. APPLIED SEALANT TO FAYING SURFACES IAW DC-8 SRM 51-1-11. INSTALLED NEW PANEL FROM STATION XAR 0.000 TO STATION XE 132.000 IAW DC-8 SRM 55-4-1 FIG 1 SHEET 1, AND 2, DC8 SRM 51-1-21. PERFORMED BALANCE TO RIGHT HAND ELEVATOR IAW DC-8 SRM 51-4-4 PAGES 1-4. FOUND WITHIN TOLERANCE MOMENT 1477.44 LBS.