What was found
DURING ROUTINE C CHECK INSPECTION, UPGRADE REPAIR OF DENT ON FORWARD LOWER FUSELAGE PLATING AFT OF NLG WW RT AFT CORNERS AT STA 16, L35R IAW EO 53-DC8-2428. MAJOR REPAIR. COMPLETED FAA FORM 8110-3 NUMBER 06260 DATED 05-29-06, SEMAN DRAWING NUMBER ED 4231 DATED 05-27-06. REMOVED EXISTING FASTENERS AS NEEDED TO REMOVE EXISTING REPAIR DOUBLER IAW DC-8 SRM 51-1-21, DC8 SRM 51-3-0. REMOVED DAMAGED AREA IAW SEMAN DRAWING NUMBER ED 4231. PERFORMED NDT INSPECTION IAW DC-8 NDT SPM PART 06-10-01-001. NO CRACKS, OR CORROSION FOUND. FABRICATED REPAIR DOUBLER, SKIN FILLER, AND FINGER DOUBLER IAW SEMAN DRAWING NUMBER 4231. CLEANED, TREATED AND PRIMED AREA AND REPAIR PARTS IAW DC-8 SRM 51-1-8B. APPLIED SEALANT TO FAYING SURF