What was found
DURING ROUTINE C CHECK INSPECTION, FOUND LT WING IB UPPER PANEL DENTED, AT STATION XW40.000. REMOVED DAMAGED SKIN IAW SRM 57-1-0 PAGE 1, SRM 51-1-21. FABRICATED SKIN WITH (AL 2024 T3 0.025) AND BONDED DOUBLER (AL 2024 T3 0.020) IAW SRM 57-7-1 FIG. 1 ITEM A, L, SRM 57-7-1 PAGE 1. BONDED BOTH PARTS WITH HYSOL IAW SRM 51-1-9. CLEANED, TREATED AND PRIMED INTERNAL SURFACE. IAW SRM 51-1-8B. APPLIED SEALANT TO FAYING SURFACES IAW SRM 51-1-11. INSTALLED NEW SKIN, IAW SRM 51-1-21.