What was found
DURING ROUTINE C-CHECK INSPECTION, LT WING OB FLAP UPPER SKIN NO STANDARD REPAIR NEAR XF 169 TO XF 213.000. PERFORMED MAJOR REPAIR IAW SRM 57-7-1 FIG. 4 T.R. 57-94 DATE 10-01-02. REMOVED PANEL PLATING WITH NO STANDARD REPAIR EXISTING IAW SRM 51-1-21. FABRICATED PANEL PLATING WITH PLATING & DOUBLER IAW SRM 57-7-1 FIG. 4 ITEM (P) AND (Q). BONDED BOTH PARTS WITH HYSOL IAW SRM 51-1-4. CLEANED, TREATED AND PRIMED AREA & PANEL PLATING INTERNAL PART IAW SRM 51-1-8B. APPLIED SEALANT TO FAYING SURFACES IAW SRM 51-1-11. INSTALLED PANEL PLATING IAW SRM 51-1-21.