What was found
DURING ROUTINE C CHECK INSPECTION FOUND RIGHT HAND ELEVATOR LOWER SKIN WITH NON STANDARD REPAIR AT STATION XE39.188. REMOVED FASTENERS IAW SRM 51-1-21. REMOVED DAMAGED AREA. FABRICATED NEW REPAIR, AND FILLERS (AL 2024 T3 0.016”) IAW SRM 55-2-1 FIG. 11 (SHEET 4, 6, 9), SRM 55-4-1 FIG. 1 (SHEET 1, 2) ITEM E AND F. BONDED BOTH PART WITH HYSOL IAW SRM 51-1-9. CLEANED, TREATED AND PRIMED AREA , AND NEW REPAIR INTERNAL SURFACE IAW SRM 51-1-8B. INSTALLED REPAIR PARTS IAW SRM 55-2-1 FIG. 11 (SHEET 4, 6, 9, 11)., SRM 51-1-21, SRM 55-2-1 FIG. 11.