What was found
DURING ROUTINE C CHECK, MODIFY CARGO DOOR JAMB CORNERS AT STATION 1420 LONGERON 34.5 RIGHT IAW AD 2004-06-06. REMOVED EXISTING REPAIR. FABRICATED REPAIR PARTS. CLEANED TREATED AND PRIMED AREA AND REPAIR PARTS. APPLIED SEALANT TO FAYING SURFACES. INSTALLED REPAIR PARTS IAW DC8 SRM 53-4-1 FIG 16 SHEET 2, DC8 SRM 53-1-0 PAGE 1, DC8 SRM 51-1-21, DC-8 SRM 51-1-8B, DC8 SRM 51-1-11, DC-8 SRM 53-4-1 FIG 16 SHEET 2 PAGE 34 ITEM “B”, DC-8 SRM 51-1-21, DC-8 SRM 51-1-20D, DC-8 SRM 51-3-1, DOUGLAS DRAWING NUMBER 5779936.