What was found
DURING ROUTINE C-CHECK INSPECTION, FOUND EXISTING REPAIR AT STATION 1430 LONGERON 36 IN CLOSE PROXIMITY TO ANOTHER EXISTING REPAIR AT THE LOWER SIDE OF (D) PIT DOOR. INCORPORATED BOTH REPAIRS INTO ONE REPAIR. (D) PIT DOOR CORNER REPAIR. REMOVED EXISTING REPAIRS. FABRICATED REPAIR PARTS. CLEANED, TREATED AND PRIMED AREA AND NEW REPAIR PARTS. APPLIED SEALANT TO FAYING SURFACES. INSTALLED NEW REPAIR PARTS, (P/N 56155372-71N) IAW SRM 53-4-1 FIG 16 SHEET 2 PAGE 34 ITEM (B), MFG DRAWING NR 5779936, SRM 51-1-21, SRM 51-1-20D, SRM 51-3-1, SRM 53-1-0 PAGE 1, SRM 51-1-8B, AND SRM 51-1-11.