What was found
DURING ROUTINE C CHECK INSPECTION, FOUND FITTING CORRODED AT STATION 75.000, LONGERON 29 LEFT. REMOVED CORROSION. FOUND OUT ALLOWABLE LIMITS. REMOVED DAMAGED FITTING. CLEANED, TREATED AND PRIMED AREA. INSTALLED NEW FITTING IAW DC-8 SRM 51-1-21, DC-8 SRM 51-3-0, DC-8 SRM 51-3-1, DC-8 SRM 51-1-8 PAGES 17-18, DC-8 SRM 53-2-0 PAGE 2P, AND DC-8 SRM 51-1-8B.