What was found
DURING ROUTINE C CHECK INSPECTION, FOUND FRAME FITTING CRACKED AT STATION FS 1160.000 LONGERON 27 RIGHT RBL 44. REMOVED CRACKED FITTING. FABRICATED NEW FITTING. HEAT TREATED NEW FITTING. PERFORMED NDT INSPECTION. NO CRACKS OR CORROSION FOUND. CLEANED, TREATED AND PRIMED AREA AND NEW FITTING. INSTALLED NEW FITTING IAW DC-8 SRM 51-3-1, DC-8 SRM 51-1-20D, DC-8 SRM 51-1-1 PAGES 1, 13, 17, DC-8 NDT SPM PART 08-00-02 TO 07, DC-8 SRM 51-1-8B, AND SEMAN DRAWING NUMBER 4708061.