What was found
DURING ROUTINE C CHECK INSPECTION, FOUND FITTING CRACKED AT STATION 879.000, LONGERON 13 RIGHT. REMOVED CRACKED FITTING. FABRICATED NEW FITTING. PERFORMED NDT INSPECTION, NO CRACKS OR CORROSION FOUND. CLEANED, TREATED AND PRIMED FITTING. INSTALLED FITTING IAW DC8 SRM 51-1-20D, DC8 SRM 51-3-1, DC8 SRM 51-1-8B, DOUGLAS DRAWING NUMBER 3779970, AND DC8 NDT SPM PART 08-00-02.