What was found
DURING ROUTINE C CHECK INSPECTION, FOUND A FITTING SPLICE CRACKED AT STATION 690.000, LONGERON 1. REMOVED DAMAGED SPLICE FITTING. FABRICATED NEW SPLICE FITTING. PERFORMED NDT INSPECTION. CLEANED, TREATED AND PRIMED AREA AND NEW SPLICE FITTING. INSTALLED NEW SPLICE FITTING IAW DC8 SRM 51-1-20D, DC8 NDT SPM PART 08-00-02 TO 07, DC8 SRM 51-1-8B, DC8 SRM 51-3-1, AND DOUGLAS DRAWING NUMBER 3753985.