What was found
DURING ROUTINE C CHECK INSPECTION, FOUND RIGHT ELEVATOR LOWER SKIN HAS A NON STANDARD REPAIR AT STATION XE272.000. REMOVED SKIN WITH EXISTING NON STANDARD REPAIR. FABRICATED NEW SKIN AND FINGER DOUBLER. BONDED BOTH PARTS WITH HYSOL. CLEANED, TREATED AND PRIMED AREA AND REPAIR PARTS. INSTALLED REPAIR PARTS. BALANCED RIGHT ELEVATOR. FOUND MOMENT WITHIN TOLERANCE LIMITS. MOMENT 1456-8 IN POUND, DC8 SRM 55-4-1 FIGURE 1 SHEET 1-2, DC8 SRM 55-1-0, DC8 SRM 55-4-1 FIGURE 1 SHEET 1-2 ITEM "E" AND "F", DC8 SRM 51-1-9, DC8 SRM 51-1-8B, DC8 SRM 51-1-21, AND DC8 SRM 51-4-4 PAGE 2-3.