What was found
DURING ROUTINE C CHECK INSPECTION, LEFT WING NUMBER 2 STUB WING HAS A NON STANDARD REPAIR AT STATION XS 250.000. REMOVED FASTENERS AS NEEDED TO PERFORM REPAIR. REMOVED DAMAGED AREA. PERFORMED NDT INSPECTION. NO CRACKS OR CORROSION FOUND AFTER DAMAGE REMOVAL. FABRICATED REPAIR PARTS. CLEANED, TREATED AND PRIMED AREA AND REPAIR PARTS. APPLIED SEALANT TO FAYING SURFACES. INSTALLED REPAIR PARTS IAW DC8 SRM 51-1-21, DC8 SRM 51-1-20D, DC8 SRM 51-3-0, DC8 SRM 51-3-1, DC8 NDT SPM PART 06-10-01-001, DC8 SRM 51-1-8B, DC8 SRM 51-1-11, FAA FORM 8110-3, NUMBER 06574 DATED 11-23-06, SEMAN DRAWING, NUMBER ED-4376 DATED 11-14-06, AND SEMAN ENGINEERING ORDER, NUMBER 2006954 DATED 11-23-06.