What was found
DURING ROUTINE C CHECK INSPECTION, FOUND RIGHT WING LEADING EDGE HAS A NON STANDARD REPAIR AT STATION XOLDI6.224. REMOVED EXISTING NON-STANDARD REPAIR. REMOVED DAMAGED AREA. PERFORMED NDT INSPECTION. NO CRACKS OR CORROSION FOUND AFTER DAMAGE REMOVAL. FABRICATED REPAIR PARTS. CLEANED, TREATED AND PRIMED AREA AND REPAIR PARTS. APPLIED SEALANT TO FAYING SURFACES. INSTALLED REPAIR PARTS DC8 SRM 51-1-21, DC8 SRM 51-3-0, DC8 SRM 51-1-20D, DC8 SRM 51-3-1, DC8 NDT SPM PART 06-10-01-001, DC8 SRM 51-1-8B, DC8 SRM 51-1-11, FAA FORM 8110-3, NUMBER 06565 DATED 11-13-06, SEMAN DRAWING, NUMBER ED-4377 DATED 11-09-06, AND SEMAN ENGINEERING ORDER, NUMBER 2006955 DATED 11-13-06.