What was found
DURING ROUTINE C CHECK INSPECTION, FOUND RIGHT WING UPPER LEADING EDGE CORRODED, BETWEEN STATIONS XFS341.500 AND XFS304.000. REMOVED FASTENERS AS NEEDED TO PERFORM REPAIR. REMOVED CORROSION. FOUND OUT OF LIMITS. REMOVED DAMAGED AREA. FABRICATED REPAIR PARTS. CLEANED, TREATED AND PRIMED AREA AND REPAIR PARTS. APPLIED SEALANT TO FAYING SURFACES. INSTALLED REPAIR PARTS IAW DC8 SRM 51-1-21, DC8 51-1-20D, DC8 SRM 51-1-8 PAGES 17-18, DC8 SRM 57-2-1 FIGURE 2G, DC8 SRM 57-2-1, FIGURE 44 DC8 SRM 57-3-1 PAGE 8 FIGURE 4 ITEM "A", DC8 SRM 51-1-8B, DC8 SRM 51-1-11, DC8 SRM 51-3-0 AND DC8 SRM 51-3-1.