What was found
DURING ROUTINE C CHECK INSPECTION FOUND A CRACKED FITTING AT STATION FS 824.000 LONGERON 14 RIGHT. REMOVED CRACKED FITTING. FABRICATED FITTING. PERFORMED NDT INSPECTION, NO CRACKS OR CORROSION FOUND. CLEANED, TREATED AND PRIMED AREA AND FITTING. INSTALLED FITTING IAW DC8 SRM 51-3-1, DC8 SRM 51-1-20D, DC8 NDT SPM PART 08-00-02 TO 07, DC8 SRM 51-1-8B AND DOUGLAS DRAWING NUMBER 4751643.