What was found
DURING ROUTINE C CHECK INSPECTION, FOUND RIGHT WING LOWER CENTRAL LEADING EDGE HAS A NON STANDARD REPAIR FROM STATION XFS304.000 TO XFS316.000. REMOVED EXISTING NON STANDARD REPAIR. REMOVED DAMAGED AREA. PERFORMED NDT INSPECTION. NO CRACK OR CORROSION FOUND, AFTER DAMAGE REMOVED. FABRICATED REPAIR PARTS. CLEANED, TREATED AND PRIMED AREA AND REPAIR PARTS. APPLIED SEALANT TO FAYING SURFACES. INSTALLED REPAIR PARTS IAW DC8 SRM 51-1-20D, DC8 SRM 51-3-1, DC8 SRM 51-1-21, DC8 SRM 51-3-0, DC8 NDT SPM PART 06-10-01-001, DC8 SRM 51-1-8B, DC8 SRM 51-1-11, SEMAN DRAWING NUMBER ED-4433 DATED 01-22-07 AND COMPLETED FAA FORM 8110-3 NUMBER 07031 DATED 01-26-07.