What was found
DURING ROUTINE C CHECK INSPECTION, FOUND LEFT WING LEADING EDGE HAS A NON STANDARD REPAIR FROM STATION XFS304.000 TO STATION XFS310.000. REMOVED EXISTING NON STANDARD REPAIR. REMOVED DAMAGED AREA. PERFORMED NDT INSPECTION. NO CRACKS OR CORROSION FOUND, AFTER DAMAGE REMOVED. FABRICATED REPAIR PARTS. CLEANED, TREATED AND PRIMED AREA AND REPAIR PARTS AS NEEDED. APPLIED SEALANT TO FAYING SURFACES. INSTALLED REPAIR PARTS IAW DC8 SRM 51-1-20D, DC8 SRM 51-3-1, DC8 SRM 51-1-21, DC8 SRM 51-3-0, DC8 NDT SPM PART 06-10-01-001,DC8 SRM 51-18B, DC8 SRM 51-1-11. SEMAN DRAWING NUMBER ED-4435 DATED 01-20-07 AND COMPLETED FAA FORM 8110-3 NUMBER 07026 DATED 01-22-07.