What was found
DURING ROUTINE C CHECK INSPECTION, FOUND LEFT WING LEADING EDGE HAS A NON STANDARD REPAIR FROM STATION XFS416.000 TO STATION XOLDI6.220. REMOVED EXISTING NON STANDARD REPAIR. REMOVED DAMAGED AREA. PERFORMED NDT INSPECTION. NO CRACKS OR CORROSION FOUND AFTER DAMAGE REMOVED. FABRICATED REPAIR PARTS. CLEANED, TREATED AND PRIMED AREA AND REPAIR PARTS AS NEEDED. APPLIED SEALANT TO FAYING SURFACES. INSTALLED REPAIR PARTS IAW DC8 SRM 51.3.1, DC8 SRM 51-1-21, DC8 SRM 51-3-0, DC8 SRM 51-1-20D, DC8 NDT SPM PART 06-10-01-001, DC8 SRM 51-1-8B, DC8 SRM 51-1-11, SEMAN DRAWING ED-4436 DATED 01-18-07, COMPLETED FAA FORM 8110-3 NUMBER 07026 DATED 01-22-07.