What was found
DURING ROUTINE C CHECK INSPECTION, RT WING OTBD L/E OUTER SECTION SHOWS 1" CRACKED AT STA XFS 885.000 (NEAR EXISTING REPAIR). PERFORMED MAJOR REPAIR IAW FAA FORM 8110-3 NR 07110 DATE 03/14/07, SEMAN DRAWING NR ED-4463. DATE 02-15-07 AND EO SEMAN NR 2007221 DATE 03-14-07. REMOVED EXISTING REPAIR DOUBLER IAW DC8 SRM 51-3-0 AND DC8 SRM 51-1-21. CUT OUT DAMAGED AREA IAW SEMAN DRAWING NR ED-4463. PERFORMED INSPECTION NDT-IAW DC8 NDT SPM PART 06-10-01-001. NO CRACK, NO CORROSION, AFTER CUT OUT DAMAGED AREA ATTACHED FORM SMN 242-2. FABRICATED REPAIR DOUBLER AL7075-T6 0.063 AND INTERNAL DOUBLER AL7075-T6 0.025 AND FILLER SKIN AL 7075-T6 0.050 AND EXTERNAL FILLER AL 7075 T6 0.063 IAW SEMAN DRAWING NR ED-4463. CL