What was found
DURING ROUTINE C CHECK INSPECTION, MAIN CARGO UPPER FLANGE BEAM WITH CRANK 1" AT STA 1540.000 RBL 39". PERFORMED MAJOR REPAIR IAW SRM 51-2-1 FIG 1 SHEET 8,12 TR NR 51-130 DATE 01/26/04. REMOVED FASTENERS IAW SRM 51-1-21, CUT DAMAGED AREA AND FABRICATED NEW FLANGE SEGMENT (AL 7075-T6 0.125) AND (02EA) REPAIR ANGLES OF (EXTRUSION 7075T6 0.125 P/N S1325214) AND FILLER AL 7075-T6.IAW SRM 51-2-1 FIG 1, SHEET 8,12, TR NR 51-130 SRM 53-5-2 FIG 3, SHEET 2, ITEM "D" SRM 51-2-0 FIG 50, SHEET 61. CLEANED TREATED AND PRIMED AREA AND REPAIR PARTS IAW SRM 51-1-8B. APPLIED SEALANT TO FAYING SURFACES IAW SRM 51-1-11. INSTALLED REPAIR PARTS IAW SRM 51-2-1, FIG 1, SHEET 8, 12, AND SRM 51-1-20D, 51-3-1. (TORQUE)