What was found
DURING ROUTINE C CHECK INSPECTION, FOUND IMPROPER REPAIR INSTALLED AT A-PIT BASKET DOOR, RIGHT FORWARD JAMB CORNER AT STATION 293 LONGERON 30 RIGHT. REMOVED EXISTING REPAIR. FABRICATED REPAIR DOUBLER, TRIPLER. CLEANED, TREATED AND PRIMED AREA AND REPAIR PARTS. APPLIED SEALANT TO FAYING SURFACE. INSTALLED REPAIR PARTS IAW DC8 SRM 51-1-20D, DC8 SRM 53-2-0 FIGURE 19 T/R NUMBER 53-136 AND 53-186, DC8 SRM 51-1-8B, DC8 SRM 51-1-11, DC8 SRM 51-1-21, AND DC8 51-3-1,AD 2005-18-07, DACO SERVICE BULLETIN DC8-53-078, AND DOUGLAS DRAWING SR08530019 AND 5750776.