What was found
DURING ROUTINE C CHECK INSPECTION, IN MAIN CARGO COMPARTMENT, FOUND CORROSION ON FITTING ABOVE MAIN LANDING GEAR WHEEL WELL CEILING BETWEEN STATION 960.000 - 980.000 RIGHT BOTTOM LINE 40". REMOVED CORROSION. FOUND OUT OF LIMITS. REMOVED CORRODED FITTING. CLEANED, TREATED AND PRIMED AREA. INSTALLED NEW FITTING, IAW DC8 SRM 51-3-1,DC8 SRM 51-1-8, DC8 SRM 53-2-0 PAGE 2P, DC8 SRM 51-1-20D, AND DC8 SRM 51-1-8B.