What was found
DURING ROUTINE C CHECK INSPECTION, FOUND MAIN CARGO COMPARTMENT HAD CORROSION ON FITTING ABOVE MAIN LANDING GEAR WHEEL WELL CEILING BETWEEN STATION 960.000 - 980.000 LEFT BOTTOM LINE 40”. REMOVED CORROSION. FOUND OUT OF LIMITS. REMOVED CORRODED FITTING. CLEANED TREATED AND PRIMED AREA. INSTALLED NEW FITTING IAW DC8 SRM 51-1-8 PAGE 17 AND 18, DC8 SRM 53-2-0 PAGE 2P DC8 SRM 51-1-21, DC8 SRM 51-1-20D, DC8 SRM 51-1-8B, AND 51-3-1.