What was found
DURING ROUTINE C CHECK INSPECTION, FOUND THE MID ACCESSORY COMPARTMENT FITTING CRACKED BETWEEN STATION 660.000 LONGERON 36 LT. REMOVED CRACKED FITTING. FABRICATED FITTING. PERFORMED NDT INSPECTION. CLEANED, TREATED AND PRIMED AREA AND REPAIR PART. INSTALLED FITTING IAW DC8 SRM 51-1-20D AND 51-3-1, REPAIR SPECIFICATION NUMBER 2003-05, DOUGLAS DRAWING NUMBER 3750497, NDT SPM PART 08-00-02 TO 07, AND DC8 SRM 51-1-8B.