What was found
DURING ROUTINE C CHECK INSPECTION, FOUND IN MAIN CARGO COMPARTMENT A CRACKED FITTING AT STATION 822.500 RIGHT BOTTOM LINE 25". REMOVED CRACKED FITTING. CLEANED, TREATED AND PRIMED AREA. INSTALLED NEW FITTING IAW DC8 SRM 51-1-20D, 51-3-1,DC8 SRM 51-1-20D, SRM 51-1-8B.