What was found
DURING ROUTINE C CHECK INSPECTION, FOUND IN MAIN CARGO COMPARTMENT A CRACKED FITTING AT STATION 702.875 RIGHT BOTTOM LINE 25". REMOVED CRACKED FITTING. CLEANED, TREATED AND PRIMED AREA. INSTALLED NEW FITTING IAW DC8 SRM 51-3-0, DC8 SRM 51-1-8B, DC8 SRM 51-1-20D, AND 51-3-1.