What was found
DURING ROUTINE C CHECK INSPECTION, FOUND RIGHT HORIZONTAL STABILIZER LEADING EDGE WITH DENT AT STATION XFS 242.000. REMOVED FASTENERS AS NEEDED TO PERFORM REPAIR. REMOVED DAMAGED AREA. FABRICATED REPAIR PARTS. CLEANED, TREATED AND PRIMED AREA, REPAIR PARTS. INSTALLED NEW FASTENERS AND REPAIR PARTS IAW DC8 SRM 52-2-1 FIGURE 4, DC8 SRM 51-1-21, 51-1-21A, DC8 SRM 55-2-1, FIGURE 4, SRM 55-3-1 FIGURE 1 SHEET 1 AND 2 ITEM "A", AND DC8 SRM 51-1-8B.