What was found
DURING ROUTINE C CHECK INSPECTION, FOUND FORWARD CARGO PANELS SUPPORT CRACK AT STATION 460 LONGERON 29LEFT. REMOVED FASTENERS AS NEEDED TO PERFORM REPAIR. FABRICATED ANGLE DOUBLER. CLEANED, TREATED AND PRIMED AREA AND REPAIR PARTS. INSTALLED NEW FASTENERS AND REPAIR PARTS IAW DC8 SRM 51-1-20D, 51-1-21, DC8 SRM 53-2-0 PAGE 2E AND 2F, DC8 SRM 51-1-8B, AND 51-3-1.