What was found
DURING ROUTINE C CHECK INSPECTION, FOUND EXTERNAL DOUBLER RIGHT FORWARD FUSELAGE FORWARD OF B-PIT DOOR HAS IMPROPER REPAIR AT STATION FS 466, LONGERON 25.5 RIGHT. REMOVED FASTENERS AS NEEDED TO PERFORM REPAIR. REMOVED EXISTING REPAIR. REMOVED DAMAGED AREA. PERFORMED NDT INSPECTION. NO CRACK, NO CORROSION FOUND AFTER INSPECTION. FABRICATED REPAIR DOUBLER, TRIPLER, FILLER SKIN, INTERNAL FINGER DOUBLER. CLEANED, TREATED AND PRIMED AREA AND REPAIR PART. INSTALLED NEW FASTENERS AND REPAIR PARTS IAW FAA FORM 8110-3 NUMBER 08086 DATED 02-27-08, SEMAN DRAWING ED-4701 DATED 02-05-08, DC8 SRM 51-1-21, DC8 SRM 51-1-20D, DC8 NDT SPM PART 06-10-01-001, DC8 SRM 51-1-8B, DC8 SRM 51-1-11, AND 51-3-1.