What was found
DURING ROUTINE C CHECK INSPECTION, FOUND MAIN CARGO FITTING CRACKED AT STATION 960.000 LONGERON19 LEFT. REMOVED CRACKED FITTING. FABRICATED FITTING. PERFORMED NDT INSPECTION. NO CRACK, NO CORROSION FOUND. CLEANED, TREATED AND PRIMED AREA AND FITTING. INSTALLED FITTING IAW DC8 SRM 51-1-20D, 51-3-1, DC8 SRM 51-1-20D, ATI REPAIR SPECIFICATION NUMBER 2003-05, DRAWING DOUGLAS 3779874, NDT SPM PART 08-00-02 TO 07, AND DC8 SRM 51-1-8B.