What was found
DURING ROUTINE C CHECK INSPECTION, FOUND LEFT OUTBOARD FLAP LOWER SKIN FORWARD SHOWS DENTS BETWEEN STATION XF 160.000 - XF 213.000. PERFORMED DETAILED VISUAL INSPECTION. NO CRACK NO CORROSION FOUND. PERFORMED MEASUREMENT DIA 2.00 BY 0.008" DEPTH WITHIN PERMISSIBLE LIMITS. APPLIED PRO-SEAL. CLEANED, TREATED, PRIMED AND PAINTED AREA IAW DC8 SRM 51-1-8B, DC8 57-1-0 PAGE 1, DC8 SRM 51-1-9 FIGURE 13B,