What was found
DURING ROUTINE C CHECK INSPECTION, FOUND MAIN CARGO INTERCOSTAL END CLIP CRACKED AT STATION 857.000 LONGERON 18 RIGHT. REMOVED CRACKED INTERCOSTAL END CLIP. FABRICATED INTERCOSTAL END CLIP. PERFORMED HEAT TREATMENT. CLEANED, TREATED AND PRIMED AREA AND INTERCOSTAL END CLIP. INSTALLED NEW INTERCOSTAL END CLIP IAW DC8 SRM 51-1-21, ATI REPAIR SPECIFICATION NUMBER 2003-05, DC8 SRM 51-1-1 PAGES 1, 13 AND 17, AND DC8 SRM 51-1-8B.