What was found
DURING ROUTINE C CHECK INSPECTION, FOUND MAIN CARGO COMPARTMENT NUMBER 5 TRACK NUT BARRIER FITTING CRACKED AT STATION 70.000. REMOVED CRACKED FITTING. FABRICATED NEW FITTING. PERFORMED MAGNETIC PARTICLE INSPECTION. NO CRACK, NO CORROSION FOUND. CLEANED, TREATED AND PRIMED AREA AND FITTING. INSTALLED NEW FITTING IAW DC8 51-3-0, DC8 SRM 51-3-1, DC8 SRM 51-3-0, ATI REPAIR SPECIFICATION 2003-05, DRAWING DOUGLAS 3774645, NDT SPM PARA 07-00-02/07, AND DC8 SRM 51-1-8B.