What was found
DURING ROUTINE C CHECK INSPECTION, FOUND MAIN CARGO COMPARTMENT AFT FITTING CRACKED AT STATION 759.000 RIGHT BOTTOM LINE 22". REMOVED CRACKED FITTING. CLEANED, TREATED AND PRIMED AREA. INSTALLED NEW FITTING IAW DC8 SRM 51-1-20D, DC8 SRM 51-3-1, AND DC8 SRM 51-1-8B.