What was found
DURING ROUTINE C CHECK INSPECTION, FOUND IMPROPER REPAIR AT STATION FS 1350 LONGERON 36. REMOVED FASTENERS AS NEEDED TO PERFORM REPAIR. REMOVED EXISTING REPAIR. REMOVED DAMAGED AREA. PERFORMED NDT INSPECTION. NO CRACK AND CORROSION FOUND. FABRICATED REPAIR DOUBLER, FILLER, FINGER DOUBLERS. CLEANED, TREATED AND PRIMED AREA AND REPAIR PARTS. INSTALLED NEW FASTENERS AND REPAIR PARTS IAW FAA FORM 8110-3 NUMBER 08198 DATED 04/25/08, DRAWING ED-4760 DATED 04/24/08, SRM 51-1-21, 51-1-20D, 51-3-0, NDT SPM PART 06-10-01-001, SRM 51-1-8B, SRM 51-1-11, AND 51-3-1.