What was found
DURING ROUTINE C CHECK INSPECTION, FOUND IMPROPER REPAIR AT STATION FS 545 LONGERON 35.75 LEFT. REMOVED FASTENERS AS NEEDED TO PERFORM REPAIR. REMOVED EXISTING REPAIR. REMOVED DAMAGED AREA. PERFORMED NDT INSPECTION. NO CRACK AND CORROSION FOUND. FABRICATED REPAIR DOUBLER, FILLER, AND FINGER DOUBLER. CLEANED, TREATED AND PRIMED AREA AND REPAIR PARTS. INSTALLED NEW FASTENERS AND REPAIR PARTS IAW FAA FORM 8110-3 NUMBER 08188 DATED 04/23/08, SEMAN DRAWING ED-4758 DATED 04/19/08, DC8 SRM 51-1-21, 51-1-20D, 51-3-0, DC8 NDT SPM PART 06-10-01-001, DC8 SRM 51-1-8B, DC8 SRM 51-1-11, AND 51-3-1.