What was found
DURING ROUTINE C CHECK INSPECTION, FOUND IMPROPER REPAIRS LOCATED AT STATION FS 653 LONGERON 26.5 LEFT. REMOVED FASTENERS AS NEEDED TO PERFORM REPAIR. REMOVED EXISTING REPAIR. PERFORMED NDT INSPECTION. NO CRACK AND CORROSION FOUND. FABRICATED REPAIR DOUBLER, TRIPLER. CLEANED, TREATED AND PRIMED AREA AND REPAIR PARTS. INSTALLED NEW FASTENERS AND REPAIR PARTS IAW FAA FORM 8110-3 NUMBER 08198 DATED 04/25/08, SEMAN DRAWING NUMBER ED-4761 DATED 04/24/08, DC8 SRM 51-1-21, 51-1-20D, DC8 NDT SPM PART 06-10-01-001, DC8 SRM 51-1-8B, DC8 SRM 51-1-11, AND 51-3-1.