What was found
DURING ROUTINE C CHECK INSPECTION, FOUND RIGHT MAIN LANDING GEAR WHEEL WELL FITTING CRACKED AT STATION 940.000 LONGERON 24. REMOVED CRACKED FRAME FITTING. FABRICATED SPLICES, DOUBLER, FILLERS. CLEANED, TREATED AND PRIMED AREA AND REPAIR PARTS. INSTALLED NEW FITTING AND REPAIR PARTS IAW DC8 SRM 53-2-0 FIGURE 8 SHEETS 1, 2, 5 AND 6, DC8 SRM 53-1-0 PAGE 1, 51-1-20D, DC8 AND SRM 51-1-8B.