What was found
DURING ROUTINE C CHECK INSPECTION, FOUND IMPROPER REPAIR AT STATION FS 45.000 LONGERON 29LT. REMOVED FASTENERS AS NEEDED TO PERFORM REPAIR. REMOVED EXISTING REPAIR. REMOVED DAMAGED AREA. FABRICATED REPAIR DOUBLER. CLEANED, TREATED AND PRIMED AREA AND REPAIR PARTS. INSTALLED NEW FASTENERS AND REPAIR PARTS IAW SRM 53-2-0 FIGURE 13 SHEET 1 TR NUMBER 53-169 SHEET 5 DATED 09-20-03, SRM 51-1-20D, SRM 53-2-0 FIGURE 13 SHEET 1 VIEW A (7001) ITEM 1, SRM 53-3-1 FIGURE 1 ITEM C, SRM 51-1-8B, SRM 51-1-11, 51-1-21, 51-1-20D AND 51-3-1.