What was found
DURING ROUTINE C CHECK INSPECTION, FOUND IMPROPER REPAIR AT XRS 74 EXTERNAL DOUBLER LEFT WHEEL WELL AFT OF MAIN LANDING GEAR TRUNNION. REMOVED FASTENERS AS NEEDED TO PERFORM REPAIR. REMOVED EXISTING REPAIR. REMOVED DAMAGED AREA. FABRICATED EXTERNAL DOUBLER. CLEANED, TREATED AND PRIMED AREA AND REPAIR PARTS. INSTALLED NEW FASTENERS AND REPAIR PART IAW AD 90-16-05, DACO SB 57-58 DATED 01-19-08, DOUGLAS DRAWING 5758978 AND 5643410, DACO SRM 51-1-11, 51-1-21, 51-1-20D AND 51-3-1, DC8 SRM 51-1-21 AND 51-1-20D.