What was found
DURING ROUTINE C CHECK INSPECTION, FOUND RIGHT ELEVATOR TRAILING EDGE LOWER SKIN CORRODED AT STATION XE 74.469. REMOVED CORROSION. FOUND OUT OF LIMITS. REMOVED EXISTING REPAIR. FABRICATED NEW SKIN, FINGER DOUBLER. BONDED PARTS AS NEEDED WITH HYSOL. CLEANED, TREATED, PRIMED AREA AND REPAIR PARTS. PERFORMED BALANCE. FOUND WITHIN LIMITS. MOMENT 1526.000 IN-POUND. INSTALLED REPAIR PARTS IAW SRM 55-4-1 FIGURE 1 SHEETS 1-2 ITEMS "E" AND "F", SRM 51-1-8 PAGES 17-18, SRM 55-2-0 PAGE 12, SRM 55-1-0 PAGE 1, SRM 51-1-21, SRM 51-1-9 TR NUMBER 51-142, SRM 51-1-9A TR NUMBER 51-141, SRM 51-1-8B, SRM 51-1-11, AND SRM 51-4-4 PAGES 1-4 TR NUMBER 51-116.