What was found
DURING ROUTINE C CHECK INSPECTION, FOUND RIGHT ELEVATOR TRAILING EDGE LOWER SKIN CORRODED AT STATION XE 147.188A - XE 156.168. REMOVED CORROSION. FOUND OUT OF LIMITS. REMOVED CORRODED SKIN. FABRICATED NEW SKIN, FINGER DOUBLER. BONDED PARTS AS NEEDED WITH HYSOL. CLEANED, TREATED, PRIMED AREA AND REPAIR PART. PERFORMED BALANCE. FOUND WITHIN LIMITS, MOMENT: 1526.0 IN-POUND. INSTALLED REPAIR PARTS IAW SRM 55-4-1 FIGURE 1 SHEETS 1-2 ITEMS "E" AND "F", SRM 51-1-8 PAGES 17-18, SRM 55-2-0 PAGE 12, SRM 55-1-0 PAGE 1, SRM 51-1-21, SRM 51-1-9 TR 51-142, SRM 51-1-9A TR 51-141, SRM 51-1-8B, SRM 51-1-11, AND SRM 51-4-4 PAGES 1-4.