What was found
DURING ROUTINE C CHECK INSPECTION, FOUND RIGHT WING NUMBER 4 STUB WING INNER FITTING CRACKED AT STATION XS 526.000. REMOVED CRACKED FITTING. FABRICATED NEW FITTING. CLEANED, TREATED, AND PRIMED AREA AND FITTING. INSTALLED FITTING IAW DC8 SRM 51-1-20D, ATI REPAIR SPECIFICATION NUMBER 2003-05, SEMAN FORM IPI NUMBER 2009017, DOUGLAS DRAWING NUMBER 5754705, DC8 SRM 51-1-8B, AND SRM 51-3-1.