What was found
DURING ROUTINE C CHECK INSPECTION, FOUND MAIN CARGO COMPARTMENT SPLICE FITTING CRACKED AT STATION 902.000 LONGERON 1. REMOVED CRACKED SPLICE FITTING. CLEANED, TREATED, AND PRIMED AREA. INSTALLED NEW SPLICE FITTING IAW DC8 SRM 51-1-20D AND SRM 51-3-1 TABLE II PAGE 2A, DC8 SRM 51-1-21, AND DC8 SRM 51-1-8B.